The Cisco UCS B-Series is a powerful compute system. I admit that it has a little learning curve to it, but in time I’ve learned to appreciate the way it works. The thing is that after a few deployments you wonder, when are the Cisco engineers going to take usability into consideration? Well, luckily there is an SDK out there that you can get from GitHub here. If you need to refresh the use of GitHub, Atom and Python check below post about it => GitHub and Atom. After some searches on Java client setting (UCS Manager GUI), I was able to put together a couple of code lines to configure a UCS B-Series. Using an input file created from an Excel Spreadsheet and saving it as a .CSV:
This example file is available as a gist: ucs-book.csv.
The following example configures a UCS B-Series with 8 blades. It uses ports 3 and 4 on both Fiber-Interconnects as Network Uplinks and creates port channels 50 and 51 with them.
The system will have three VLANs:
- vMotion with id 50
- Management with id 51
- Production with id 200
The script can take as many VLANs as you want from the ucs-book.csv file and it will create those, but it will not allocate them to any vNIC template by default. At this point, there is an option to omit the iSCSI or the FC with two boolean variables at the beginning or the script. Download it from GitHub => ucs-config
To test all of this you could download the UCS Manager Emulator from Cisco and use Fusion to provision a new UCS B-Series. This is a basic and raw script, you would need to change the path to the .csv file and I can’t guarantee that it will work on your system and of course I am not responsible for what happens to it. I would recommend to use it in you development environment only until you become familiar with the DSK, enjoy.
#!python #import section import csv #UCS Connection Handle from ucsmsdk.ucshandle import UcsHandle #Create Organization from ucsmsdk.mometa.org.OrgOrg import OrgOrg #UUID Pool from ucsmsdk.mometa.uuidpool.UuidpoolPool import UuidpoolPool from ucsmsdk.mometa.uuidpool.UuidpoolBlock import UuidpoolBlock #VLAN from ucsmsdk.mometa.fabric.FabricVlan import FabricVlan #Sever Pool from ucsmsdk.mometa.compute.ComputePool import ComputePool from ucsmsdk.mometa.compute.ComputePooledSlot import ComputePooledSlot #Maintenance Policy from ucsmsdk.mometa.lsmaint.LsmaintMaintPolicy import LsmaintMaintPolicy #Power Policy from ucsmsdk.mometa.power.PowerPolicy import PowerPolicy #Create IP Pool from ucsmsdk.mometa.ippool.IppoolPool import IppoolPool from ucsmsdk.mometa.ippool.IppoolBlock import IppoolBlock #Create MAC Pool from ucsmsdk.mometa.macpool.MacpoolPool import MacpoolPool from ucsmsdk.mometa.macpool.MacpoolBlock import MacpoolBlock #Create Network Control Policy from ucsmsdk.mometa.nwctrl.NwctrlDefinition import NwctrlDefinition from ucsmsdk.mometa.dpsec.DpsecMac import DpsecMac #FC WWNN and WWPN Pools from ucsmsdk.mometa.fcpool.FcpoolInitiators import FcpoolInitiators from ucsmsdk.mometa.fcpool.FcpoolBlock import FcpoolBlock #Create vNIC Templates from ucsmsdk.mometa.vnic.VnicLanConnTempl import VnicLanConnTempl from ucsmsdk.mometa.vnic.VnicEtherIf import VnicEtherIf #Create Local Disk Conf Policy from ucsmsdk.mometa.storage.StorageLocalDiskConfigPolicy import StorageLocalDiskConfigPolicy #Create Boot Policy from ucsmsdk.mometa.lsboot.LsbootPolicy import LsbootPolicy from ucsmsdk.mometa.lsboot.LsbootVirtualMedia import LsbootVirtualMedia from ucsmsdk.mometa.lsboot.LsbootStorage import LsbootStorage from ucsmsdk.mometa.lsboot.LsbootLocalStorage import LsbootLocalStorage from ucsmsdk.mometa.lsboot.LsbootUsbFlashStorageImage import LsbootUsbFlashStorageImage #Create HBA Template from ucsmsdk.mometa.vnic.VnicSanConnTempl import VnicSanConnTempl from ucsmsdk.mometa.vnic.VnicFcIf import VnicFcIf #Configuring Uplink ports from ucsmsdk.mometa.fabric.FabricEthLanEp import FabricEthLanEp #Configure Port Channels from ucsmsdk.mometa.fabric.FabricEthLanPc import FabricEthLanPc from ucsmsdk.mometa.fabric.FabricEthLanPcEp import FabricEthLanPcEp #Create Service Profile Template from ucsmsdk.mometa.ls.LsServer import LsServer from ucsmsdk.mometa.ls.LsVConAssign import LsVConAssign from ucsmsdk.mometa.vnic.VnicEther import VnicEther from ucsmsdk.mometa.vnic.VnicFc import VnicFc from ucsmsdk.mometa.vnic.VnicFcIf import VnicFcIf from ucsmsdk.mometa.vnic.VnicFcNode import VnicFcNode from ucsmsdk.mometa.ls.LsRequirement import LsRequirement from ucsmsdk.mometa.ls.LsPower import LsPower from ucsmsdk.mometa.fabric.FabricVCon import FabricVCon #Are we having iSCSI to the Hosts? iSCSI = True #Are we having FC to the hosts? FC = False #Create the handle handle = UcsHandle("192.168.67.148","admin","password",secure=False) #login into UCS manager handle.login() #reading variables from the ucs workbook my_file=open("/Users/javirodz/Documents/ucs-book.csv", "r") my_csv_file = csv.reader(my_file) for row in my_csv_file: if row[0] == "Organization Name": my_Org = row[1] my_Full_Path_Org = "org-root/org-%s" % my_Org elif row[0] == "KVM Starting IP Address": my_kvm_pool_first = row[1] elif row[0] == "KVM Primary DNS IP Address": my_Primary_DNS = row[1] elif row[0] == "KVM Secondary DNS IP Address": my_Secondary_DNS = row[1] elif row[0] == "KVM Gateway": my_KVM_Gateway = row[1] elif row[0] == "KVM Ending IP Address": my_kvm_last_addr = row[1] elif row[0] == "Service Profile Template Name": my_SPT = row[1] elif row[0] == "Service Profile Name Seed": my_SP_Name = row[1] elif row[0] == "VLAN Name": VLAN_Name = row i=1 while i < len(VLAN_Name): i = i + 1 elif row[0] == "VLAN ID": VLAN_ID = row i=1 while i < len(VLAN_ID): i = i + 1 else: print "Bad Robot" #Create Sub Organization mo = OrgOrg(parent_mo_or_dn="org-root", name=my_Org, descr="Sub Organization") handle.add_mo(mo) handle.commit() #Create Production VLANs k = 1 while k < len(VLAN_Name): mo = FabricVlan(parent_mo_or_dn="fabric/lan", sharing="none", name=VLAN_Name[k], id=VLAN_ID[k], mcast_policy_name="", policy_owner="local", default_net="no", pub_nw_name="", compression_type="included") handle.add_mo(mo) handle.commit() k = k+1 #Create UUID Pool mo = UuidpoolPool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", prefix="derived", descr="UUID Pool", assignment_order="sequential", name="UUID_POOL") mo_1 = UuidpoolBlock(parent_mo_or_dn=mo, to="0001-000000000100", r_from="0001-000000000001") handle.add_mo(mo) handle.commit() #Create a Server Pool mo = ComputePool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", name="Server_Pool", descr="Server Pool") mo_1 = ComputePooledSlot(parent_mo_or_dn=mo, slot_id="1", chassis_id="1") mo_2 = ComputePooledSlot(parent_mo_or_dn=mo, slot_id="2", chassis_id="1") mo_3 = ComputePooledSlot(parent_mo_or_dn=mo, slot_id="3", chassis_id="1") mo_4 = ComputePooledSlot(parent_mo_or_dn=mo, slot_id="4", chassis_id="1") mo_5 = ComputePooledSlot(parent_mo_or_dn=mo, slot_id="5", chassis_id="1") mo_6 = ComputePooledSlot(parent_mo_or_dn=mo, slot_id="7", chassis_id="1") mo_7 = ComputePooledSlot(parent_mo_or_dn=mo, slot_id="8", chassis_id="1") handle.add_mo(mo) handle.commit() #Create Maintenance Policy mo = LsmaintMaintPolicy(parent_mo_or_dn=my_Full_Path_Org, uptime_disr="user-ack", name="User_Ack", descr="User Ack", trigger_config="on-next-boot", sched_name="", policy_owner="local") handle.add_mo(mo) handle.commit() #Create Power Policy mo = PowerPolicy(parent_mo_or_dn=my_Full_Path_Org, fan_speed="any", policy_owner="local", name="No_Cap", prio="no-cap", descr="No Cap") handle.add_mo(mo) handle.commit() #Create IP Pool mo = IppoolPool(parent_mo_or_dn=my_Full_Path_Org, is_net_bios_enabled="disabled", name="ext_mgmt", descr="KVM", policy_owner="local", ext_managed="internal", supports_dhcp="disabled", assignment_order="sequential") mo_1 = IppoolBlock(parent_mo_or_dn=mo, prim_dns=my_Primary_DNS, r_from=my_kvm_pool_first, def_gw=my_KVM_Gateway, sec_dns=my_Secondary_DNS, to=my_kvm_last_addr) handle.add_mo(mo) handle.commit() #Create MAC Pools mo = MacpoolPool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", descr="Mamagement FI-A", assignment_order="sequential", name="MGMT-A") mo_1 = MacpoolBlock(parent_mo_or_dn=mo, to="00:25:B5:A0:00:0F", r_from="00:25:B5:A0:00:00") handle.add_mo(mo) handle.commit() mo = MacpoolPool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", descr="Mamagement FI-B", assignment_order="sequential", name="MGMT-B") mo_1 = MacpoolBlock(parent_mo_or_dn=mo, to="00:25:B5:B0:00:0F", r_from="00:25:B5:B0:00:00") handle.add_mo(mo) handle.commit() mo = MacpoolPool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", descr="Production FI-A", assignment_order="sequential", name="VM-A") mo_1 = MacpoolBlock(parent_mo_or_dn=mo, to="00:25:B5:A1:00:0F", r_from="00:25:B5:A1:00:00") handle.add_mo(mo) handle.commit() mo = MacpoolPool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", descr="Production FI-B", assignment_order="sequential", name="VM-B") mo_1 = MacpoolBlock(parent_mo_or_dn=mo, to="00:25:B5:B1:00:0F", r_from="00:25:B5:B1:00:00") handle.add_mo(mo) handle.commit() if(iSCSI): mo = MacpoolPool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", descr="iSCSI FI-A", assignment_order="sequential", name="iSCSI-A") mo_1 = MacpoolBlock(parent_mo_or_dn=mo, to="00:25:B5:A2:00:0F", r_from="00:25:B5:A2:00:00") handle.add_mo(mo) handle.commit() mo = MacpoolPool(parent_mo_or_dn=my_Full_Path_Org, policy_owner="local", descr="iSCSI FI-B", assignment_order="sequential", name="iSCSI-B") mo_1 = MacpoolBlock(parent_mo_or_dn=mo, to="00:25:B5:B3:00:0F", r_from="00:25:B5:B3:00:00") handle.add_mo(mo) handle.commit() #End Create MAC Pools #Create Network Control Policy mo = NwctrlDefinition(parent_mo_or_dn=my_Full_Path_Org, lldp_transmit="disabled", name="CDP_EN", lldp_receive="disabled", mac_register_mode="only-native-vlan", policy_owner="local", cdp="enabled", uplink_fail_action="link-down", descr="CDP Enable") mo_1 = DpsecMac(parent_mo_or_dn=mo, forge="allow", policy_owner="local", name="", descr="") handle.add_mo(mo) handle.commit() #FC WWNN and WWPN Pools if(FC): mo = FcpoolInitiators(parent_mo_or_dn=my_Full_Path_Org, name="WWNN_Pool", policy_owner="local", descr="WWNN Pool", assignment_order="sequential", purpose="node-wwn-assignment") mo_1 = FcpoolBlock(parent_mo_or_dn=mo, to="20:00:00:25:B5:A0:00:FF", r_from="20:00:00:25:B5:A0:00:00") handle.add_mo(mo) handle.commit() mo = FcpoolInitiators(parent_mo_or_dn=my_Full_Path_Org, name="WWPN_Pool-A", policy_owner="local", descr="WWPN Pool FI-A", assignment_order="sequential", purpose="port-wwn-assignment") mo_1 = FcpoolBlock(parent_mo_or_dn=mo, to="20:01:00:25:B5:A0:00:0F", r_from="20:01:00:25:B5:A0:00:00") handle.add_mo(mo) handle.commit() mo = FcpoolInitiators(parent_mo_or_dn=my_Full_Path_Org, name="WWPN_Pool-B", policy_owner="local", descr="WWPN Pool FI-B", assignment_order="sequential", purpose="port-wwn-assignment") mo_1 = FcpoolBlock(parent_mo_or_dn=mo, to="20:01:00:25:B5:B0:00:0F", r_from="20:01:00:25:B5:B0:00:00") handle.add_mo(mo) handle.commit() #Create vNIC Templates mo = VnicLanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="MGMT-A", descr="Management FI-A", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", mtu="1500", policy_owner="local", qos_policy_name="", ident_pool_name="MGMT-A", cdn_source="vnic-name", nw_ctrl_policy_name="CDP_EN") mo_1 = VnicEtherIf(parent_mo_or_dn=mo, default_net="yes", name="Mgmt") mo_2 = VnicEtherIf(parent_mo_or_dn=mo, default_net="no", name="vMotion") handle.add_mo(mo) handle.commit() mo = VnicLanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="MGMT-B", descr="Management FI-B", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", mtu="1500", policy_owner="local", qos_policy_name="", ident_pool_name="MGMT-B", cdn_source="vnic-name", nw_ctrl_policy_name="CDP_EN") mo_1 = VnicEtherIf(parent_mo_or_dn=mo, default_net="yes", name="Mgmt") mo_2 = VnicEtherIf(parent_mo_or_dn=mo, default_net="no", name="vMotion") handle.add_mo(mo) handle.commit() mo = VnicLanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="VM-A", descr="Production FI-A", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", mtu="1500", policy_owner="local", qos_policy_name="", ident_pool_name="VM-A", cdn_source="vnic-name", nw_ctrl_policy_name="CDP_EN") #Depending on the VLANs that will pass wot the NIC: mo_1 = VnicEtherIf(parent_mo_or_dn=mo, default_net="no", name=Production) handle.add_mo(mo) handle.commit() mo = VnicLanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="VM-B", descr="Production FI-B", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", mtu="1500", policy_owner="local", qos_policy_name="", ident_pool_name="VM-B", cdn_source="vnic-name", nw_ctrl_policy_name="CDP_EN") #Depending on the VLANs that will pass wot the NIC: mo_1 = VnicEtherIf(parent_mo_or_dn=mo, default_net="no", name=Production) handle.add_mo(mo) handle.commit() if(iSCSI): #Create iSCSI-A VLAN on FI-A (ID 2550) mo = FabricVlan(parent_mo_or_dn="fabric/eth-estc/A", sharing="none", name="iSCSI-A", id="2550", mcast_policy_name="", policy_owner="local", default_net="no", pub_nw_name="", compression_type="included") handle.add_mo(mo) handle.commit() #Create iSCSI-B VLAN on FI-B (ID 2551) mo = FabricVlan(parent_mo_or_dn="fabric/eth-estc/B", sharing="none", name="iSCSI-B", id="2551", mcast_policy_name="", policy_owner="local", default_net="no", pub_nw_name="", compression_type="included") handle.add_mo(mo) handle.commit() mo = VnicLanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="iSCSI-A", descr="iSCSI FI-A", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", mtu="1500", policy_owner="local", qos_policy_name="", ident_pool_name="iSCSI-A", cdn_source="vnic-name", nw_ctrl_policy_name="CDP_EN") mo_1 = VnicEtherIf(parent_mo_or_dn=mo, default_net="yes", name="iSCSI-A") handle.add_mo(mo) handle.commit() mo = VnicLanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="iSCSI-B", descr="iSCSI FI-B", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", mtu="1500", policy_owner="local", qos_policy_name="", ident_pool_name="iSCSI-B", cdn_source="vnic-name", nw_ctrl_policy_name="CDP_EN") mo_1 = VnicEtherIf(parent_mo_or_dn=mo, default_net="yes", name="iSCSI-B") handle.add_mo(mo) handle.commit() #Create Local Disk Conf Policy (any-configuration) mo = StorageLocalDiskConfigPolicy(parent_mo_or_dn=my_Full_Path_Org, protect_config="yes", name="Local_Disk_CP", descr="Local Disk Configuration Policy Desc", flex_flash_raid_reporting_state="enable", flex_flash_state="enable", policy_owner="local", mode="any-configuration") handle.add_mo(mo) handle.commit() #Create Boot Policy (boot from SD) mo = LsbootPolicy(parent_mo_or_dn=my_Full_Path_Org, name="Boot_Policy", descr="Boot Policy Desc", reboot_on_update="no", policy_owner="local", enforce_vnic_name="yes", boot_mode="legacy") mo_1 = LsbootVirtualMedia(parent_mo_or_dn=mo, access="read-write-drive", lun_id="0", mapping_name="", order="2") mo_2 = LsbootStorage(parent_mo_or_dn=mo, order="1") mo_2_1 = LsbootLocalStorage(parent_mo_or_dn=mo_2, ) mo_2_1_1 = LsbootUsbFlashStorageImage(parent_mo_or_dn=mo_2_1, order="1") handle.add_mo(mo) handle.commit() #Create HBA Template if(FC): mo = VnicSanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="fc-a", descr="", stats_policy_name="default", switch_id="A", pin_to_group_name="", policy_owner="local", qos_policy_name="", ident_pool_name="WWPN_Pool-A", max_data_field_size="2048") mo_1 = VnicFcIf(parent_mo_or_dn=mo, name="default") handle.add_mo(mo) handle.commit() mo = VnicSanConnTempl(parent_mo_or_dn=my_Full_Path_Org, templ_type="updating-template", name="fc-b", descr="", stats_policy_name="default", switch_id="B", pin_to_group_name="", policy_owner="local", qos_policy_name="", ident_pool_name="WWPN_Pool-B", max_data_field_size="2048") mo_1 = VnicFcIf(parent_mo_or_dn=mo, name="default") handle.add_mo(mo) handle.commit() #Configuring Uplink ports #FI-A Port-3 mo = FabricEthLanEp(parent_mo_or_dn="fabric/lan/A", eth_link_profile_name="default", name="", flow_ctrl_policy="default", admin_speed="10gbps", auto_negotiate="yes", usr_lbl="", slot_id="1", admin_state="enabled", port_id="3") handle.add_mo(mo) handle.commit() #FI-A Port-4 mo = FabricEthLanEp(parent_mo_or_dn="fabric/lan/A", eth_link_profile_name="default", name="", flow_ctrl_policy="default", admin_speed="10gbps", auto_negotiate="yes", usr_lbl="", slot_id="1", admin_state="enabled", port_id="4") handle.add_mo(mo) handle.commit() #FI-B Port-3 mo = FabricEthLanEp(parent_mo_or_dn="fabric/lan/B", eth_link_profile_name="default", name="", flow_ctrl_policy="default", admin_speed="10gbps", auto_negotiate="yes", usr_lbl="", slot_id="1", admin_state="enabled", port_id="3") handle.add_mo(mo) handle.commit() #FI-B Port-4 mo = FabricEthLanEp(parent_mo_or_dn="fabric/lan/B", eth_link_profile_name="default", name="", flow_ctrl_policy="default", admin_speed="10gbps", auto_negotiate="yes", usr_lbl="", slot_id="1", admin_state="enabled", port_id="4") handle.add_mo(mo) handle.commit() #Configure Port Channels #PC-50 with FI-A P3 and FI-A P4 mo = FabricEthLanPc(parent_mo_or_dn="fabric/lan/A", name="PC-50", descr="", flow_ctrl_policy="default", admin_speed="10gbps", auto_negotiate="yes", admin_state="enabled", oper_speed="10gbps", port_id="50", lacp_policy_name="default") mo_1 = FabricEthLanPcEp(parent_mo_or_dn=mo, eth_link_profile_name="default", name="", auto_negotiate="yes", slot_id="1", admin_state="enabled", port_id="3") mo_2 = FabricEthLanPcEp(parent_mo_or_dn=mo, eth_link_profile_name="default", name="", auto_negotiate="yes", slot_id="1", admin_state="enabled", port_id="4") handle.add_mo(mo) handle.commit() #PC-51 with FI-B P3 and FI-B P4 mo = FabricEthLanPc(parent_mo_or_dn="fabric/lan/B", name="PC-51", descr="", flow_ctrl_policy="default", admin_speed="10gbps", auto_negotiate="yes", admin_state="enabled", oper_speed="10gbps", port_id="51", lacp_policy_name="default") mo_1 = FabricEthLanPcEp(parent_mo_or_dn=mo, eth_link_profile_name="default", name="", auto_negotiate="yes", slot_id="1", admin_state="enabled", port_id="3") mo_2 = FabricEthLanPcEp(parent_mo_or_dn=mo, eth_link_profile_name="default", name="", auto_negotiate="yes", slot_id="1", admin_state="enabled", port_id="4") handle.add_mo(mo) handle.commit() #Create Service Profile Template if (FC and not iSCSI): mo = LsServer(parent_mo_or_dn="org-root/org-Test_Org", vmedia_policy_name="", ext_ip_state="none", bios_profile_name="", mgmt_fw_policy_name="", agent_policy_name="", mgmt_access_policy_name="", dynamic_con_policy_name="", kvm_mgmt_policy_name="", sol_policy_name="", uuid="0", descr="SPT Description", stats_policy_name="default", policy_owner="local", ext_ip_pool_name="ext-mgmt", boot_policy_name="Boot_Policy", usr_lbl="", host_fw_policy_name="", vcon_profile_name="", ident_pool_name="UUID_POOL", src_templ_name="", type="initial-template", local_disk_policy_name="Local_Disk_CP", scrub_policy_name="", power_policy_name="default", maint_policy_name="User_Ack", name=my_SPT, resolve_remote="yes") mo_1 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="1", transport="ethernet", vnic_name="MGMT-A") mo_2 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="2", transport="ethernet", vnic_name="MGMT-B") mo_3 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="3", transport="ethernet", vnic_name="VM-A") mo_4 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="4", transport="ethernet", vnic_name="VM-B") mo_5 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="5", transport="fc", vnic_name="fc-a") mo_6 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="6", transport="fc", vnic_name="fc-b") mo_7 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="MGMT-A", order="1", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="MGMT-A", addr="derived") mo_8 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="MGMT-B", order="2", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="MGMT-B", addr="derived") mo_9 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="VM-A", order="3", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="VM-A", addr="derived") mo_10 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="VM-B", order="4", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="VM-B", addr="derived") mo_11 = VnicFc(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", addr="derived", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", pers_bind="disabled", order="5", pers_bind_clear="no", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", max_data_field_size="2048", nw_templ_name="fc-a", name="fc-a") mo_11_1 = VnicFcIf(parent_mo_or_dn=mo_11, name="") mo_12 = VnicFc(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", addr="derived", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", pers_bind="disabled", order="6", pers_bind_clear="no", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", max_data_field_size="2048", nw_templ_name="fc-b", name="fc-b") mo_12_1 = VnicFcIf(parent_mo_or_dn=mo_12, name="") mo_13 = VnicFcNode(parent_mo_or_dn=mo, ident_pool_name="WWNN_Pool", addr="pool-derived") mo_14 = LsRequirement(parent_mo_or_dn=mo, restrict_migration="no", name="Server_Pool", qualifier="") mo_15 = LsPower(parent_mo_or_dn=mo, state="admin-up") mo_16 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="1", inst_type="auto") mo_17 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="2", inst_type="auto") mo_18 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="3", inst_type="auto") mo_19 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="4", inst_type="auto") handle.add_mo(mo) handle.commit() if(iSCSI and not FC): mo = LsServer(parent_mo_or_dn="org-root/org-Test_Org", vmedia_policy_name="", ext_ip_state="none", bios_profile_name="", mgmt_fw_policy_name="", agent_policy_name="", mgmt_access_policy_name="", dynamic_con_policy_name="", kvm_mgmt_policy_name="", sol_policy_name="", uuid="0", descr="SPT Desc", stats_policy_name="default", policy_owner="local", ext_ip_pool_name="ext-mgmt", boot_policy_name="Boot_Policy", usr_lbl="", host_fw_policy_name="", vcon_profile_name="", ident_pool_name="UUID_POOL", src_templ_name="", type="updating-template", local_disk_policy_name="Local_Disk_CP", scrub_policy_name="", power_policy_name="default", maint_policy_name="User_Ack", name=my_SPT, resolve_remote="yes") mo_1 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="1", transport="ethernet", vnic_name="MGMT-A") mo_2 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="2", transport="ethernet", vnic_name="MGMT-B") mo_3 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="3", transport="ethernet", vnic_name="VM-A") mo_4 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="4", transport="ethernet", vnic_name="VM-B") mo_5 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="5", transport="ethernet", vnic_name="iSCSI-A") mo_6 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="6", transport="ethernet", vnic_name="iSCSI-B") mo_7 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="MGMT-A", order="1", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="MGMT-A", addr="derived") mo_8 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="MGMT-B", order="2", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="MGMT-B", addr="derived") mo_9 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="VM-A", order="3", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="VM-A", addr="derived") mo_10 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="VM-B", order="4", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="VM-B", addr="derived") mo_11 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="iSCSI-A", order="5", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="iSCSI-A", addr="derived") mo_12 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="iSCSI-B", order="6", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="iSCSI-B", addr="derived") mo_13 = VnicFcNode(parent_mo_or_dn=mo, ident_pool_name="node-default", addr="pool-derived") mo_14 = LsRequirement(parent_mo_or_dn=mo, restrict_migration="no", name="Server_Pool", qualifier="") mo_15 = LsPower(parent_mo_or_dn=mo, state="admin-up") mo_16 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="1", inst_type="auto") mo_17 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="2", inst_type="auto") mo_18 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="3", inst_type="auto") mo_19 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="4", inst_type="auto") handle.add_mo(mo) handle.commit() if(iSCSI and FC): mo = LsServer(parent_mo_or_dn="org-root/org-Test_Org", vmedia_policy_name="", ext_ip_state="none", bios_profile_name="", mgmt_fw_policy_name="", agent_policy_name="", mgmt_access_policy_name="", dynamic_con_policy_name="", kvm_mgmt_policy_name="", sol_policy_name="", uuid="0", descr="SPT Description", stats_policy_name="default", policy_owner="local", ext_ip_pool_name="ext-mgmt", boot_policy_name="Boot_Policy", usr_lbl="", host_fw_policy_name="", vcon_profile_name="", ident_pool_name="UUID_POOL", src_templ_name="", type="updating-template", local_disk_policy_name="Local_Disk_CP", scrub_policy_name="", power_policy_name="default", maint_policy_name="User_Ack", name=my_SPT, resolve_remote="yes") mo_1 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="1", transport="ethernet", vnic_name="MGMT-A") mo_2 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="2", transport="ethernet", vnic_name="MGMT-B") mo_3 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="3", transport="ethernet", vnic_name="VM-A") mo_4 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="4", transport="ethernet", vnic_name="VM-B") mo_5 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="5", transport="ethernet", vnic_name="iSCSI-A") mo_6 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="6", transport="ethernet", vnic_name="iSCSI-B") mo_7 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="7", transport="fc", vnic_name="fc-a") mo_8 = LsVConAssign(parent_mo_or_dn=mo, admin_vcon="any", admin_host_port="ANY", order="8", transport="fc", vnic_name="fc-b") mo_9 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="MGMT-A", order="1", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="MGMT-A", addr="derived") mo_10 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="MGMT-B", order="2", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="MGMT-B", addr="derived") mo_11 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="VM-A", order="3", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="VM-A", addr="derived") mo_12 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="VM-B", order="4", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="VM-B", addr="derived") mo_13 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", name="iSCSI-A", order="5", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="iSCSI-A", addr="derived") mo_14 = VnicEther(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", nw_ctrl_policy_name="", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", name="iSCSI-B", order="6", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", mtu="1500", nw_templ_name="iSCSI-B", addr="derived") mo_15 = VnicFc(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", addr="derived", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="A", pin_to_group_name="", pers_bind="disabled", order="7", pers_bind_clear="no", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", max_data_field_size="2048", nw_templ_name="fc-a", name="fc-a") mo_15_1 = VnicFcIf(parent_mo_or_dn=mo_15, name="") mo_16 = VnicFc(parent_mo_or_dn=mo, cdn_prop_in_sync="yes", addr="derived", admin_host_port="ANY", admin_vcon="any", stats_policy_name="default", admin_cdn_name="", switch_id="B", pin_to_group_name="", pers_bind="disabled", order="8", pers_bind_clear="no", qos_policy_name="", adaptor_profile_name="VMWare", ident_pool_name="", cdn_source="vnic-name", max_data_field_size="2048", nw_templ_name="fc-b", name="fc-b") mo_16_1 = VnicFcIf(parent_mo_or_dn=mo_16, name="") mo_17 = VnicFcNode(parent_mo_or_dn=mo, ident_pool_name="WWNN_Pool", addr="pool-derived") mo_18 = LsRequirement(parent_mo_or_dn=mo, restrict_migration="no", name="Server_Pool", qualifier="") mo_19 = LsPower(parent_mo_or_dn=mo, state="admin-up") mo_20 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="1", inst_type="auto") mo_21 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="2", inst_type="auto") mo_22 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="3", inst_type="auto") mo_23 = FabricVCon(parent_mo_or_dn=mo, placement="physical", fabric="NONE", share="shared", select="all", transport="ethernet,fc", id="4", inst_type="auto") handle.add_mo(mo) handle.commit() # Logout after script is executed handle.logout() my_file.close()
By the way, there is another script “clean-ucs.py” that will undo whatever the configuration script does, in case that you need to go back and forth with it.
No comments:
Post a Comment